Journal of Technologic Dentistry 2013; 35(1): 29-35
Published online March 30, 2013
https://doi.org/10.14347/kadt.2013.35.1.029
© Korean Academy of Dental Technology
김기백;김수진;김재홍;김지환;
고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;
Kim, Ki-Baek;Kim, Su-Jin;Kim, Jae-Hong;Kim, Ji-Hwan;
Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;
Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(
Keywords: CAD-CAM,Digital,Scanner,
Journal of Technologic Dentistry 2013; 35(1): 29-35
Published online March 30, 2013 https://doi.org/10.14347/kadt.2013.35.1.029
Copyright © Korean Academy of Dental Technology.
김기백;김수진;김재홍;김지환;
고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;
Kim, Ki-Baek;Kim, Su-Jin;Kim, Jae-Hong;Kim, Ji-Hwan;
Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University;
Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(
Keywords: CAD-CAM,Digital,Scanner,