닫기

Ex) Article Title, Author, Keywords

Journal of Technologic Dentistry 2015; 37(1): 9-15

Published online March 30, 2015

https://doi.org/10.14347/kadt.2015.37.1.9

© Korean Academy of Dental Technology

치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교

배소연;박진영;김지환;김혜영;김명배;김웅철;

고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;대한 치과CAD/CAM가공 학회;고려대학교 대학원 보건과학과 치의기공전공;

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines

Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul;

Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Korea academy of CAD/CAM Dental technology;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;

Abstract

Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{mu}m$ of mean value compared to $4.44{mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

Keywords: Dental CAD/CAM system,Accuracy,Three-dimensional superimposition analysis,

Article

Journal of Technologic Dentistry 2015; 37(1): 9-15

Published online March 30, 2015 https://doi.org/10.14347/kadt.2015.37.1.9

Copyright © Korean Academy of Dental Technology.

치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교

배소연;박진영;김지환;김혜영;김명배;김웅철;

고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;대한 치과CAD/CAM가공 학회;고려대학교 대학원 보건과학과 치의기공전공;

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines

Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul;

Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;Korea academy of CAD/CAM Dental technology;Department of Dental Laboratory Science & Engineering, College of Health Science, Graduate School, Korea University;

Abstract

Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{mu}m$ of mean value compared to $4.44{mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

Keywords: Dental CAD/CAM system,Accuracy,Three-dimensional superimposition analysis,

Stats or Metrics

Share this article on

  • line

Most KeyWord ?

What is Most Keyword?

  • It is most registrated keyword in articles at this journal during for 2 years.

Journal of Technologic Dentistry

eISSN 2288-5218
pISSN 1229-3954
qr-code Download