닫기

Ex) Article Title, Author, Keywords

Journal of Technologic Dentistry 2016; 38(2): 57-62

Published online June 30, 2016

https://doi.org/10.14347/kadt.2016.38.2.57

© Korean Academy of Dental Technology

2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가

김총명;전진훈;이재준;김지환;김웅철;

고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;

Precision evaluation of crown prosthesis manufactured by two bur and three bur

Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul;

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;

Abstract

Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{pm}4.1{mu}m$ and $19.1{pm}2.8{mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{pm}1.9{mu}m$ and $13.3{pm}2.5{mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

Keywords: Dental CAD/CAM systems,Milling bur,Milling machine,Precision,Three-dimensional evaluation,5-axis milling,

Article

Journal of Technologic Dentistry 2016; 38(2): 57-62

Published online June 30, 2016 https://doi.org/10.14347/kadt.2016.38.2.57

Copyright © Korean Academy of Dental Technology.

2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가

김총명;전진훈;이재준;김지환;김웅철;

고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;

Precision evaluation of crown prosthesis manufactured by two bur and three bur

Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul;

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;

Abstract

Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{pm}4.1{mu}m$ and $19.1{pm}2.8{mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{pm}1.9{mu}m$ and $13.3{pm}2.5{mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

Keywords: Dental CAD/CAM systems,Milling bur,Milling machine,Precision,Three-dimensional evaluation,5-axis milling,

Stats or Metrics

Share this article on

  • line

Most KeyWord ?

What is Most Keyword?

  • It is most registrated keyword in articles at this journal during for 2 years.

Journal of Technologic Dentistry

eISSN 2288-5218
pISSN 1229-3954
qr-code Download