Journal of Technologic Dentistry 2016; 38(2): 63-68
Published online June 30, 2016
https://doi.org/10.14347/kadt.2016.38.2.63
© Korean Academy of Dental Technology
김총명;김재홍;김지환;김웅철;
고려대학교 대학원 보건과학과 치의기공전공;경동대학교 치기공학과;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;
Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul;
Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Technology, Medical campus, KyungDong University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;
Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results:
Keywords: Dental CAD/CAM,Internal adaptation,Provisional crown,Subtractive method,Three-dimensional,5-axis milling,
Journal of Technologic Dentistry 2016; 38(2): 63-68
Published online June 30, 2016 https://doi.org/10.14347/kadt.2016.38.2.63
Copyright © Korean Academy of Dental Technology.
김총명;김재홍;김지환;김웅철;
고려대학교 대학원 보건과학과 치의기공전공;경동대학교 치기공학과;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;
Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul;
Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Technology, Medical campus, KyungDong University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;
Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results:
Keywords: Dental CAD/CAM,Internal adaptation,Provisional crown,Subtractive method,Three-dimensional,5-axis milling,