Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Technology, Medical campus, KyungDong University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;

Abstract

Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{pm}18.2$, $44.8{pm}10.0$, and $52.1{pm}8.3{mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

Keywords: Dental CAD/CAM,Internal adaptation,Provisional crown,Subtractive method,Three-dimensional,5-axis milling,

Article

Journal of Technologic Dentistry 2016; 38(2): 63-68

Published online June 30, 2016 https://doi.org/10.14347/kadt.2016.38.2.63

Copyright © Korean Academy of Dental Technology.

5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가

김총명;김재홍;김지환;김웅철;

고려대학교 대학원 보건과학과 치의기공전공;경동대학교 치기공학과;고려대학교 대학원 보건과학과 치의기공전공;고려대학교 대학원 보건과학과 치의기공전공;

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine

Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul;

Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Technology, Medical campus, KyungDong University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University;

Abstract

Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{pm}18.2$, $44.8{pm}10.0$, and $52.1{pm}8.3{mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

Keywords: Dental CAD/CAM,Internal adaptation,Provisional crown,Subtractive method,Three-dimensional,5-axis milling,