닫기

Ex) Article Title, Author, Keywords

Journal of Technologic Dentistry 2017; 39(4): 227-233

Published online December 30, 2017

https://doi.org/10.14347/kadt.2017.39.4.277

© Korean Academy of Dental Technology

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구

김재홍;이정수;심정석;

동남보건대학교 치기공과;신구대학교 치기공과;신구대학교 치기공과;

Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner

Kim, Jae-Hong;Lee, Jung-Soo;Shim, Jeong-Seok;

Department of Dental Technology, Dongnam Health University;Department of Dental Laboratory Technology, Shingu University;Department of Dental Laboratory Technology, Shingu University;

Abstract

Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Keywords: 3D dental scanner,Accuracy,Digital model,Optical source,

Article

Journal of Technologic Dentistry 2017; 39(4): 227-233

Published online December 30, 2017 https://doi.org/10.14347/kadt.2017.39.4.277

Copyright © Korean Academy of Dental Technology.

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구

김재홍;이정수;심정석;

동남보건대학교 치기공과;신구대학교 치기공과;신구대학교 치기공과;

Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner

Kim, Jae-Hong;Lee, Jung-Soo;Shim, Jeong-Seok;

Department of Dental Technology, Dongnam Health University;Department of Dental Laboratory Technology, Shingu University;Department of Dental Laboratory Technology, Shingu University;

Abstract

Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Keywords: 3D dental scanner,Accuracy,Digital model,Optical source,

Stats or Metrics

Share this article on

  • line

Most KeyWord ?

What is Most Keyword?

  • It is most registrated keyword in articles at this journal during for 2 years.

Journal of Technologic Dentistry

eISSN 2288-5218
pISSN 1229-3954
qr-code Download