닫기

Ex) Article Title, Author, Keywords

Original Article

Split Viewer

Journal of Technologic Dentistry 2024; 46(3): 73-83

Published online September 30, 2024

https://doi.org/10.14347/jtd.2024.46.3.73

© Korean Academy of Dental Technology

적층 빌드 방향이 가철성 국소의치 금속 구조물의 정확도와 내부 다공성에 미치는 영향

함건희1, 김지환1,2

1고려대학교 일반대학원 보건과학과 치의기공학전공, 2고려대학교 L-HOPE 공동체-기반 토탈 러닝헬스시스템 교육연구단

Received: August 1, 2024; Revised: September 5, 2024; Accepted: September 19, 2024

Effect of build orientation on the accuracy and internal porosity of removable partial denture metal frameworks

Geon Hee Ham1 , Ji-Hwan Kim1,2

1Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University Graduate School, Seoul, Korea
2L-HOPE Program for Community-Based Total Learning Health Systems, Korea University, Seoul, Korea

Correspondence to :
Ji-Hwan Kim
Department of Dental Laboratory Science and Engineering, Graduate School, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
E-mail: kjh2804@korea.ac.kr
https://orcid.org/0000-0003-3889-2289

Received: August 1, 2024; Revised: September 5, 2024; Accepted: September 19, 2024

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose: This study aimed to investigate whether the accuracy and internal porosity of removable partial denture frameworks differ depending on the build direction in the selective laser melting method.
Methods: A partially edentulous maxillary study model was scanned, and the anterior–posterior palatal bar was then digitally designed. The angles formed between the z-axis and the path of the insertion and removal were divided into five groups: –60°, –30°, 0°, 30°, and 60°. For each group, three removable partial denture metal frameworks were fabricated and used as specimens. The inner surface of each sample was scanned and superimposed on the design file to obtain the root mean square (RMS) value, and the average RMS value of each group was measured. One sample was randomly selected from each group, and the equivalent diameter and sphericity of the pores were analyzed using industrial X-ray three-dimensional computed tomography. To compare statistical differences between groups, the Kruskal–Wallis test of SPSS Statistics ver. 27.0 (IBM) was used (α=0.05).
Results: The average RMS values of the whole inner surface accuracy of the specimens were in the order of –60°<0°<–30°<30°<60° (p<0.05). The equivalent diameter and sphericity of internal pores were significantly different among groups (p<0.001).
Conclusion: The build orientation of the selective laser melting method influences the accuracy and internal porosity of removable partial denture frameworks.

Keywords: Accuracy, Porosity, Removable partial denture, Selective laser melting

Article

Original Article

Journal of Technologic Dentistry 2024; 46(3): 73-83

Published online September 30, 2024 https://doi.org/10.14347/jtd.2024.46.3.73

Copyright © Korean Academy of Dental Technology.

적층 빌드 방향이 가철성 국소의치 금속 구조물의 정확도와 내부 다공성에 미치는 영향

함건희1, 김지환1,2

1고려대학교 일반대학원 보건과학과 치의기공학전공, 2고려대학교 L-HOPE 공동체-기반 토탈 러닝헬스시스템 교육연구단

Received: August 1, 2024; Revised: September 5, 2024; Accepted: September 19, 2024

Effect of build orientation on the accuracy and internal porosity of removable partial denture metal frameworks

Geon Hee Ham1 , Ji-Hwan Kim1,2

1Department of Dental Laboratory Science and Engineering, College of Health Science, Korea University Graduate School, Seoul, Korea
2L-HOPE Program for Community-Based Total Learning Health Systems, Korea University, Seoul, Korea

Correspondence to:Ji-Hwan Kim
Department of Dental Laboratory Science and Engineering, Graduate School, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Korea
E-mail: kjh2804@korea.ac.kr
https://orcid.org/0000-0003-3889-2289

Received: August 1, 2024; Revised: September 5, 2024; Accepted: September 19, 2024

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose: This study aimed to investigate whether the accuracy and internal porosity of removable partial denture frameworks differ depending on the build direction in the selective laser melting method.
Methods: A partially edentulous maxillary study model was scanned, and the anterior–posterior palatal bar was then digitally designed. The angles formed between the z-axis and the path of the insertion and removal were divided into five groups: –60°, –30°, 0°, 30°, and 60°. For each group, three removable partial denture metal frameworks were fabricated and used as specimens. The inner surface of each sample was scanned and superimposed on the design file to obtain the root mean square (RMS) value, and the average RMS value of each group was measured. One sample was randomly selected from each group, and the equivalent diameter and sphericity of the pores were analyzed using industrial X-ray three-dimensional computed tomography. To compare statistical differences between groups, the Kruskal–Wallis test of SPSS Statistics ver. 27.0 (IBM) was used (α=0.05).
Results: The average RMS values of the whole inner surface accuracy of the specimens were in the order of –60°<0°<–30°<30°<60° (p<0.05). The equivalent diameter and sphericity of internal pores were significantly different among groups (p<0.001).
Conclusion: The build orientation of the selective laser melting method influences the accuracy and internal porosity of removable partial denture frameworks.

Keywords: Accuracy, Porosity, Removable partial denture, Selective laser melting

Stats or Metrics

Share this article on

  • line

Most KeyWord ?

What is Most Keyword?

  • It is most registrated keyword in articles at this journal during for 2 years.

Journal of Technologic Dentistry

eISSN 2288-5218
pISSN 1229-3954
qr-code Download